Microvisor system calls include the following functions for application timekeeping operations:


Return values and errors

return-values-and-errors page anchor

All of the functions described below return a 32-bit integer that is one of the values from the standard Microvisor enumeration MvStatus. All possible error values for a given system call are provided with each function's description.

Success is always signaled by a return value of zero (MV_STATUS_OKAY).


Gets the current value of Microvisor's free-running microsecond clock

Declaration

declaration page anchor
extern enum MvStatus mvGetMicroseconds(uint64_t *usec);
ParameterDescription
usecA pointer to non-secure memory into which the microsecond counter value will be written by Microvisor
Error ValueDescription
MV_STATUS_PARAMETERFAULTusec does not reference memory accessible to the application

Microvisor's microsecond clock starts from zero when Microvisor is run, and counts up from then on. It has no relation to — and may drift with respect to — wall time.

1
// Tick counters
2
uint64_t last_tick = 0;
3
uint64_t tick = 0;
4
5
while (true) {
6
enum MvStatus status = mvGetMicroseconds(&tick);
7
if (status == MV_STATUS_OKAY && tick - last_tick > LED_FLASH_PERIOD_US) {
8
// Toggle the USER LED's GPIO pin every LED_FLASH_PERIOD_US microseconds
9
HAL_GPIO_TogglePin(LED_GPIO_BANK, LED_GPIO_PIN);
10
last_tick = tick;
11
}
12
}

Gets the current time in non-leap microseconds since the Unix epoch

extern enum MvStatus mvGetWallTime(uint64_t *usec);
ParameterDescription
usecA pointer to non-secure memory into which the microsecond wall time will be written by Microvisor
Error ValueDescription
MV_STATUS_PARAMETERFAULTusec does not reference memory accessible to the application
MV_STATUS_TIMENOTSETThe device's RTC has not yet been set from the server

This will return MV_STATUS_TIMENOTSET on restart until the real-time clock (RTC) is synchronized with the server. Clock synchronization takes place periodically during application lifecycle: for example, it is updated regularly while the device is connected, and again when the device connects or re-connects. The value written into usec may therefore jump forward or backward in response to an updated time from the server.

This example, which modifies a section of the FreeRTOS demo code(link takes you to an external page) logging.c file's _write() function, shows how to use the 64-bit wall clock time to feed the standard gmtime() and strftime() functions (defined in <time.h>) to create a timestamp string to prefix any output sent to printf(). The code uses the same source to include the millisecond time:

1
2022-05-10 13:40:57.489 [DEBUG] Temperature: 25.31
2
2022-05-10 13:40:57.490 [DEBUG] Network handle: 321452355
3
2022-05-10 13:40:57.491 [DEBUG] HTTP channel handle: 1702803732
4
2022-05-10 13:40:57.492 [DEBUG] Sending HTTP request
5
2022-05-10 13:40:58.023 [ERROR] HTTP status code: 429
6
2022-05-10 13:40:58.024 [DEBUG] HTTP channel closed

Here is the code:

1
// Prepare and add a timestamp to log output if we can.
2
// If we can't, we show no time
3
char timestamp[64] = {0};
4
uint64_t usec = 0;
5
enum MvStatus status = mvGetWallTime(&usec);
6
if (status == MV_STATUS_OKAY) {
7
// Get the second and millisecond times
8
time_t sec = (time_t)usec / 1000000;
9
time_t msec = (time_t)usec / 1000;
10
11
// Write time string as "2022-05-10 13:30:58.XXX "
12
strftime(timestamp, 64, "%F %T.XXX ", gmtime(&sec));
13
14
// Insert the millisecond time over the XXX
15
sprintf(&timestamp[20], "%03u ", (unsigned)(msec % 1000));
16
}
17
18
// Write out the time string. Confirm that Microvisor
19
// has accepted the request to write data to the channel.
20
uint32_t time_chars = 0;
21
size_t len = strlen(timestamp);
22
if (len > 0) {
23
status = mvWriteChannelStream(log_handles.channel, (const uint8_t*)timestamp, len, &time_chars);
24
if (status != MV_STATUS_OKAY) {
25
errno = EIO;
26
return -1;
27
}
28
}
29
30
// Write out the message string. Confirm that Microvisor
31
// has accepted the request to write data to the channel.
32
uint32_t msg_chars = 0;
33
status = mvWriteChannelStream(log_handles.channel, (const uint8_t*)ptr, length, &msg_chars);
34
if (status == MV_STATUS_OKAY) {
35
// Return the number of characters written to the channel
36
return time_chars + msg_chars;
37
} else {
38
errno = EIO;
39
return -1;
40
}